Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Article in English | IMSEAR | ID: sea-45824

ABSTRACT

Glucose oxidase paper strips for semiquantitative determination of glucose in urine are commercially available but details of their preparation are not published. The purpose of this study was to produce such strips, using a coupled enzyme glucose oxidase-peroxidase reaction which would yield purple color with ortho-tolidine, and safranin upon dipping into urine containing glucose. In this present study, without any special equipment, special humidity and temperature control, the new reagent strip named R-strip could be successfully prepared in the atmospheric conditions of Thailand. R-strips were evaluated against random urine added with various amounts of glucose in comparison with a commercial strip (T-strip), Benedict's test, and a commercial tablet (C-tablet), routinely used in laboratories. The developed strips were found to be as specific as T-strip and more sensitive than other tests.


Subject(s)
Diagnostic Tests, Routine , Glucose/metabolism , Glycosuria/diagnosis , Humans , Paper , Reagent Kits, Diagnostic , Sensitivity and Specificity , Thailand , Urinalysis/instrumentation
2.
Rev. bras. anal. clin ; 32(1): 15-20, 2000. tab
Article in Portuguese | LILACS | ID: lil-306213

ABSTRACT

O ácido ascórbico, frequentemente ingerido como suplemento alimentar, é altamente eliminado pela urina e pode interferir nos ensaios laboratoriais que utilizam reaçöes de óxido-reduçäo, como por exemplo, os sistemas de reaçöes de peroxidaçäo usados para a detecçäo de glicose e hemoglobina urinárias. O objetivo desse estudo foi avaliar a interferência do ácido ascórbico nessas determinaçöes em relaçäo à dose de vitamina C ingerida e ao tempo de coleta das amostras. Indivíduos saudáveis (n=13) consumiram doses de 0,15 a 4,0 g/dia de vitamina C e as determinaçöes foram realizadas em urinas coletadas 4, 12, 24 e 48h após a ingestäo. Quantidades crescentes de glicose e hemoglobina foram acionadas às amostras de urina e os ensaios foram realizados com as tiras reagentes Rapignost e Multistix. Os resultados demonstraram que ocorreram interferências significativas nas amostras de 4 e 12h, inclusive com as menores doses de vitamina C e, embora em menor grau, também nas amostras de 24 e 48h após a ingestäo de 2 e 4g de vitamina C. A tira reagente Multistix foi ligeiramente mais resistente. Para prevenir resultados falso-negativos, sugerimos a suspensäo da ingestäo de altas doses de vitamina C, 72h antes da coleta da amostra para a realizaçäo do exame de urina


Subject(s)
Humans , Male , Female , Ascorbic Acid/urine , Glycosuria/diagnosis , Hemoglobinuria , Urinalysis
3.
Rev. chil. infectol ; 15(2): 107-11, 1998. tab
Article in Spanish | LILACS | ID: lil-245439

ABSTRACT

La meningitis bacteriana aguda (MBA) es un cuadro grave de alto porcentaje de secuelas y alta letalidad, por lo que el laboratorio clínico tiene un papel fundamental en el diagnóstico precoz. Dado que es de gran utilidad disponer de métodos sencillos se evaluó la utilidad de la tira reactiva de orina Combur 10R (para los parámetros de glucosa, proteínas y leucocitos) y del resto de los exámenes de laboratorio en muestras de LCR en la obtención de un diagnóstico rápido de MBA. Para esto se estudiaron 87 muestras de LCR que ingresaron al Laboratorio de Urgencia del Hospital Clínico de la Pontificia Universidad Católica de Chile proveniente de pacientes con sospecha clínica de MBA. A estos se les realizó estudio citoquímico, recuento celular, tinción de Gram, test de aglutinación por látex y la tira reactiva de orina Combur 10MR, evaluando visualmente los parámetros de glucosa, proteínas y leucocitos. De los 87 LCR analizados, en 13 el diagnóstico definitivo fue MBA, en 2 meningitis viral y en 72 otros. La sensibilidad y especificadad diagnóstica de la tira reactiva para dos parámetros (cualquier combinación) fueron de 100 por ciento y 87,8 por ciento respectivamente. Para tres parámetros positivos la sensibilidad fue de 76,9 por ciento, que aumentó al 84,6 por ciento si se complementa con la información de la tinción de Gram y aun 92,3 por ciento si se agrega a lo anterior el test de aglutinación por látex. Se concluye que la tira reactiva de orina Combur 10MR es un método diagnóstico suficientemente sensible, rápido y simple que puede ser utilizado como método de aproximación diagnóstica en MBA. Dado el rendimiento y alto costo del test de aglutinación por látex, se recomienda reservarlo para aquellos casos en que los otros métodos diagnóticos orienten fuertemente al diagnóstico de MBA


Subject(s)
Humans , Meningitis, Bacterial/urine , Reagent Strips , Glucose/cerebrospinal fluid , Glycosuria/diagnosis , Leukocytes , Meningitis, Bacterial/cerebrospinal fluid , Proteinuria/diagnosis , Latex Fixation Tests/methods
5.
Rev. cuba. endocrinol ; 3(1): 20-3, ene.-jun. 1992. ilus
Article in Spanish | LILACS | ID: lil-120919

ABSTRACT

Comparamos los resultados obtenidos por 2 métodos de determinación de glucosa en orina: polarimétrico, con uso del Laserpol 1 y semicuantitativo, con el uso de las tiras reactivas VISUAL. Encontramos una magnifica correlación entre ambos métodos (r = 0,331) los cuales pudieran emplearse, de acuerdo con los requerimientos del momento, con suficiente confiabilidad. El primero debe ser utilizado cuando se requiera glucosuria de 24 horas como seguimiento y el segundo lo recomendamos en aquellos casos de urgencia que requieren el resultado en pocos minutos


Subject(s)
Humans , Diabetes Mellitus/urine , Glycosuria/diagnosis , Reagent Strips
6.
AMB rev. Assoc. Med. Bras ; 32(7/8): 115-7, jul.-ago. 1986. tab
Article in Portuguese | LILACS | ID: lil-37719

ABSTRACT

Analisam-se os resultados de diferentes testes de rastreamento para o diagnóstico do diabete mélito gestacional (DMG). Compara-se a eficiência da medida da glicosúria, glicemia de jejum e glicemia 1 hora após sobrecarga oral de 50g de glicose (teste oral simplificado) para indicar a presença de DMG. Realiza-se o teste oral de sobrecarga de glicose completo em 106 pacientes, estabelecendo-se o diagnóstico de DMG em doze delas. Conclue-se que o teste oral simplificado - adotando-se o valor crítico de glicemia de 135mg/dl - apresenta os melhores índices de eficiência para detecçäo da DMG


Subject(s)
Pregnancy , Adolescent , Adult , Humans , Female , Blood Glucose/analysis , Glucose Tolerance Test , Glycosuria/diagnosis , Pregnancy in Diabetics/diagnosis
7.
Bol. Hosp. San Juan de Dios ; 33(1): 5-13, ene.-feb. 1986. ilus, tab
Article in Spanish | LILACS | ID: lil-45980

ABSTRACT

Es conocido que los diabéticos, en particular los Tipo I, deben realizar autocontrol de sus parámetros bioquímicos, especialmente glicemia, glucosuria y cetonuria, para adaptar y modificar sus dosis de insulina y mantenerse en un rango metabólico lo más cercano a lo normal. En los últimos años han aparecido sistemas rápidos de laboratório llamados "métodos de autocontrol", en forma de cintas que en un extremo tienen sólidamente fijada la zona reactiva conteniendo las enzimas y cromógenos necesarios; la intensidad del color se puede comparar en forma visual con la de la escala cromática que aparece en el envase; esta determinación es semicuantitativa. En este trabajo evaluamos la confiabilidad del método para glucosuria con Diabur Test 5000 y para glicemia con Haemoglukotest 20-800, comparando los resultados obtenidos por los pacientes con los métodos químicos: de óxido-reducción (reactivo de Fehling) para las glucosurias y enzimáticos con hexoquinasa para las glicemias. Pacientes diabéticos Tipo I (n = 7) y Tipo II (n = 7) determinaron 20 glucosurias cada uno, obteniéndose ecuaciones de regresión con coeficiente de correlación desde 0,82 a 0,97 (p < 0,001) y desviaciones de la curva estimada Sxy desde 2,2 a 11,2; estas determinaciones también fueron realizadas por personal entrenado y se obtuvo un "r" desde 0,86 a 0,97 y Sxy 2.0 a 9,6. Para evaluar el Haemoglikotest, 84 pacientes realizaron sólo las lecturas de las cintas, haciendo la metódica un personal entrenado, lográndose un r = 0,97 (p < 0,0001) con Sxy = 5,3. Cuanto todo el proceso fue realizado por pacientes en autocontrol (n = 50), se obtuvo un r = 0,84 (p < 0,001) con Sxy = 38,1. Estos resultados indican que estos métodos semicuantitativos para glicemia y glucosuria son confiables al ser realizados por los pacientes y pueden aplicarlos en su autocontrol


Subject(s)
Humans , Male , Female , Diabetes Mellitus/prevention & control , Glycosuria/diagnosis , Self Care
9.
Rev. boliv. ginecol. obstet ; 6-1(2): 9-13, 1983. tab
Article in Spanish | LILACS | ID: lil-238414

ABSTRACT

Se trata de un estudio prospectivo sobre flujo genital en 73 pacientes gestantes, en las que se practicò examen en fresco del flujo que luego se tratò con agentes tòpicos, estableciendose la utilidad d la terapèutica mediante examen en fresco posterior. Se propone como una alternativa para el tratamiento de las colpitis en las pacientes de bajos recursos econòmicos, asi como para su empleo en areas perifèricas y rurales


Subject(s)
Humans , Female , Pregnancy , Adult , Gene Frequency/genetics , Pregnancy/statistics & numerical data , Uterus/embryology , Vulva/physiology , Epithelium/embryology , Gestational Age , Glycosuria/diagnosis
10.
Arch. argent. pediatr ; 69(5): 204-206, 1971 Jul. tab
Article in Spanish | BINACIS, LILACS | ID: biblio-1159932

ABSTRACT

En 25 niños tratados con cefalotina se investigó prueba de Coombs directa y color de la orina frente a test reductores de cobre (clinitest). De 25 niños: prueba de Coombs directa: todas fueron negativas. Clinitest: 8 orinas positivas. Glucocinta: todas negativas. En el curso del trabajo se describe la importancia, significado y hallazgo de esta investigación y se recalca la diferencia hallada con la de los adultos que presentan con frecuencia reacciones de Coombs positivas.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Coombs Test , Cephalothin/therapeutic use , Diabetes Mellitus/diagnosis , Glucose Oxidase , Glycosuria/diagnosis , False Positive Reactions
SELECTION OF CITATIONS
SEARCH DETAIL